Search results for "Finite-element analysis"

showing 4 items of 4 documents

On the severity of aortic stenosis in ascending aortic aneurysm: A computational tool to examine ventricular-arterial interaction and aortic wall str…

2020

Abstract An ascending thoracic aortic aneurysm (ATAA) is a life-threatening cardiovascular consequence of vessel dilatation that portends adverse events and death. From a clinical perspective, ATAA should not be treated as an isolated disease, and surgery is often carried out in the presence of AS, aortic insufficiency or a calcified valve leaflet. Aortic stenosis (AS) is common in ATAAs and leads to both vessel rigidity and left ventricular (LV) impairment. In this study, lumped-parameter modeling and computational analysis were used to assess the change in the wall shear stress (WSS) and intramural wall stress of patient-specific ATAA models with different degrees of AS (i.e., mild to sev…

Aortic valvemedicine.medical_specialtyHemodynamicsThoracic aortic aneurysmImaging dataAortic aneurysmInternal medicinemedicineGeneral Materials ScienceIn patientFinite-element analysisCivil and Structural EngineeringShear stressbusiness.industryAortic stenosisMechanical EngineeringAscending thoracic aortic aneurysmCondensed Matter Physicsmedicine.diseaseAortic wallStenosismedicine.anatomical_structureMechanics of Materialscardiovascular systemCardiologyCFDbusinessMechanics Research Communications
researchProduct

Simulation of left ventricular outflow tract (LVOT) obstruction in transcatheter mitral valve-in-ring replacement.

2020

Left ventricular outflow tract (LVOT) obstruction is a feared complication of transcatheter mitral valve replacement (TMVR). This procedure leads to an elongation of LVOT in the left ventricle (namely, the neoLVOT), ultimately portending hemodynamic impairment and death. This study sought to understand the biomechanical implications of LVOT obstruction in two patients who underwent TMVR as an "off-label" application of the Edwards SAPIEN 3 (S3) Ultra transcatheter heart valve (THV). A computational framework of TMVR was developed to assess the neoLVOT area and quantify the sub-aortic flow structure. We observed that the annuloplasty ring serves as the key anchor zone of S3 Ultra THV. A good…

medicine.medical_specialtyCardiac Catheterizationmedicine.medical_treatment0206 medical engineeringBiomedical EngineeringBiophysicsHemodynamics02 engineering and technologyVentricular Outflow ObstructionFluid-solid interaction03 medical and health sciences0302 clinical medicineInternal medicineMitral valveMedicineVentricular outflow tractHumansFinite-element analysisHeart valveHeart Valve Prosthesis Implantationbusiness.industryMitral valve replacementSettore ING-IND/34 - Bioingegneria Industriale020601 biomedical engineeringmedicine.anatomical_structureTreatment OutcomeVentricleHeart Valve ProsthesisCardiologyMitral ValvebusinessComplicationTranscatheter mitral valve replacement030217 neurology & neurosurgeryEdwards sapienMedical engineeringphysics
researchProduct

Transcatheter Heart Valve Implantation in Bicuspid Patients with Self-Expanding Device

2021

Bicuspid aortic valve (BAV) patients are conventionally not treated by transcathether aortic valve implantation (TAVI) because of anatomic constraint with unfavorable outcome. Patient-specific numerical simulation of TAVI in BAV may predict important clinical insights to assess the conformability of the transcathether heart valves (THV) implanted on the aortic root of members of this challenging patient population. We aimed to develop a computational approach and virtually simulate TAVI in a group of n.6 stenotic BAV patients using the self-expanding Evolut Pro THV. Specifically, the structural mechanics were evaluated by a finite-element model to estimate the deformed THV configuration in …

Aortic valveTechnologymedicine.medical_specialtybicuspid aortic valveQH301-705.5medicine.medical_treatment0206 medical engineeringDiastoleBioengineering02 engineering and technology030204 cardiovascular system & hematologyBicuspid aortic valve Finite-element analysis Fluid–solid interaction Transcatheter aortic valve implantationArticle03 medical and health sciences0302 clinical medicineBicuspid aortic valveInternal medicinemedicine.arterymedicineCardiac skeletonHeart valveBiology (General)transcatheter aortic valve implantationAortabusiness.industryTSettore ING-IND/34 - Bioingegneria IndustrialeStentmedicine.diseasefluid–solid interaction020601 biomedical engineeringAortic wallmedicine.anatomical_structurefinite-element analysiscardiovascular systemCardiologybusinessBioengineering
researchProduct

Modeling Right Ventricle Failure After Continuous Flow Left Ventricular Assist Device: A Biventricular Finite-Element and Lumped-Parameter Analysis

2017

The risk of right ventricle (RV) failure remains a major contraindication for continuous-flow left ventricular assist device (CF-LVAD) implantation in patients with heart failure. It is therefore critical to identify the patients who will benefit from early intervention to avoid adverse outcomes. We sought to advance the computational modeling description of the mechanisms underlying RV failure in LVAD-supported patients. RV failure was studied by computational modeling of hemodynamic and cardiac mechanics using lumped-parameter and biventricular finite element (FE) analysis. Findings were validated by comparison of bi-dimensional speckle-tracking echocardiographic strain assessment of the …

MaleCardiac CatheterizationCardiac outputVentricular Dysfunction Rightmedicine.medical_treatmentHemodynamicsSpeckle tracking echocardiography02 engineering and technology030204 cardiovascular system & hematologySeverity of Illness IndexRight ventricular failure Left ventricular assist device Speckle-tracking echocardiography Lumped-parameter Finite-element analysis.Ventricular Function LeftVentricular Dysfunction Left0302 clinical medicineRisk FactorsMedicineModels CardiovascularMiddle AgedTreatment Outcomemedicine.anatomical_structureEchocardiographyCardiologyFemaleCardiology and Cardiovascular MedicineAdultmedicine.medical_specialtyFinite Element Analysis0206 medical engineeringBiomedical EngineeringProsthesis DesignProsthesis Implantation03 medical and health sciencesInternal medicineSettore ING-IND/12 - Misure Meccaniche E TermicheHumansComputer SimulationInterventricular septumContraindicationRetrospective StudiesHeart Failurebusiness.industryHemodynamicsmedicine.disease020601 biomedical engineeringVentricleVentricular assist deviceHeart failureVentricular Function RightHeart-Assist DevicesbusinessCardiovascular Engineering and Technology
researchProduct